| Management number | 211042883 | Release Date | 2026/04/04 | List Price | $26.38 | Model Number | 211042883 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
Product Name: 64CH DC 7-27V Multifunction Modbus DI-DO Module Isolate Input Darlington Output for PLC Relay HMI IC Tester Industrial ControlPackage inlcuded:1PCS DC 9V 12V 24V 64DI-64DO RS485 NPN Input & Output ModuleDescription:1 Working voltage: DC 7-27V (9V 12V 24V)2 Working current: 9-49MA3 64 optically isolated input ports, NPN input4 64 Darlington transistor outputs (ULN2803 NPN output)5 The default command has a variety of output modes: open, close, Momentary, self-locking, interlocking, delay six output modes6 The input port can remotely control the output port of another board through the RS485 bus7 MODBUS command 1 supports 03 06 16 function codes, MODBUS command 2 supports 01/02/03/05/06/15/16 function codes8 The maximum delay of 1 MODBUS command is 255 seconds9 In MODBUS command mode, up to 64 devices can be used in parallel10 Input and output two terminal blocks:64P DC3 2.54MM Socket/66P 2.54MM PIN10 The default baud rate is 9600BPS, you can choose the baud rate by jumper:1200/2400/4800/19200/38400/57600/115200BPS11 Sizes (with box):296*115*37MM12 Weight (with box): 390g13 Maximum load: The maximum load current of each channel is 300MA, the total maximum load current is 1A2. Glossary:Vo: equal to the working voltage DC 7-27VO1/2/3…64: Output ports, low-level output''Open'': the output port outputs low level''Close'': The output port outputs high impedance (floating)Momentary : Enter the Momentary command, the Rreceiver Relay is Open, delay of 0.5 seconds after, Relay is Close;Toggle : Enter the Toggle command, the Rreceiver Relay is Open, Enter the Toggle command again, Relay is Close;Latched : Enter the Channel 1 Latched command, the receiver Channel 1 is Open, the Channel 2 is Close.Enter the Channel 2 Latched command the receiver Channel 2 is Open, the Channel 1 is Close.Enter the Channel 3 Latched command the receiver Channel 1 is Close, the Channel 2 is Close.Delay : Enter the Delay command, the Rreceiver Relay is Open, delay of 0-9999 seconds(MODBUS command is 0-255 seconds )after, Relay is Close;During the delay, Eter the Close command, immediately close the relayApplicationPLC IO expansion boardSmart Home,Home Automation ,Wiser Home;PTZ CameraSecurity MonitoringIdentification system;IP CameraLED Lamp DriversAutomatic curtain controlIC testerDigital switch input and output detectionOutput descriptionThe single output load capacity is not greater than 300MA, and the output load capacity of the entire board is not greater than 1A.1A resettable fuse limits the maximum output current. If you need the total output load to be greater than 1A, please replace the fuse.There are two types of terminal blocks for input and outputINPUT:64P DC3 Socket(No GND)66P 2.54MM PIN(With GND)OUTPUT:64P DC3 Socket(No Vo)66P 2.54MM PIN(With Vo)
| UPC | 765057025993 |
|---|---|
| Brand Name | eletechsup |
| Part Number | N4D4F64_R |
| Coil Voltage | 12 Volts |
| Contact Type | Normally Open |
| Manufacturer | eletechsup |
| Operation Mode | Automatic |
| Included Components | With DIN BOX |
| Maximum Switching Current | 1 Amps |
| Maximum Switching Voltage | 27 Volts |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form